Sonic
Air
Steam
Pipe & Vent
Variable
Shale
Specialty
The steam assisted flare relies on the energy associated with pressurized steam to entrain air and provide the mixing required for smokeless flaring. Additionally, the water / gas reaction improves the hydrocarbon combustion breakdown while reducing the flame temperatures. Both enhance the steam flare’s ability to reduce smoke formation.
The GBA-Corona GCT steam assist flare is part of the utility line of flares. This economical flare uses a ring of nozzles to inject steam into the base of the waste gas flame. The nozzles are angled to improve the air entrainment and maximize the air / gas mixing. For larger flares, a center stream nozzle can easily be incorporated.
For more stringent applications, the GCT-AJ series provides low noise and high efficiency.